APU Length Counter

From NESdev Wiki
Revision as of 08:10, 5 May 2013 by Ulfalizer (talk | contribs) (s/APU clock/frame counter clock/)
Jump to navigationJump to search

The length counter provides automatic duration control for the NES APU waveform channels. Once loaded with a value, it can optionally count down (when the length counter halt flag is clear). Once it reaches zero, the corresponding channel is silenced.

Address Bitfield Description
$4015 ---d.nt21 DMC control and length counter enabled flags (write)
 
$4000 ssHe.eeee Pulse channel 1 duty cycle, length counter halt, and envelope (write)
$4004 ssHe.eeee Pulse channel 2 duty cycle, length counter halt, and envelope (write)
$400C --He.eeee Noise channel length counter halt and envelope (write)
bit 5 --H- ---- Halt length counter (this bit is also the envelope's loop flag)
 
$4008 Hlll.llll Triangle channel length counter halt and linear counter load (write)
bit 7 H--- ---- Halt length counter (this bit is also the linear counter's control flag)
 
$4003 LLLL.Lttt Pulse channel 1 length counter load and timer (write)
$4007 LLLL.Lttt Pulse channel 2 length counter load and timer (write)
$400B LLLL.Lttt Triangle channel length counter load and timer (write)
$400F LLLL.L--- Noise channel length counter load (write)
bits 7-3 LLLL L--- If the enabled flag is set, the length counter is loaded with entry L of the length table:
     |  0   1   2   3   4   5   6   7    8   9   A   B   C   D   E   F
-----+----------------------------------------------------------------
00-0F  10,254, 20,  2, 40,  4, 80,  6, 160,  8, 60, 10, 14, 12, 26, 14,
10-1F  12, 16, 24, 18, 48, 20, 96, 22, 192, 24, 72, 26, 16, 28, 32, 30
Side effects The envelope is restarted, for pulse channels phase is reset, for triangle the halt flag is set.

Clocking

When the enabled bit is cleared (via $4015), the length counter is forced to 0 and cannot be changed until enabled is set again (the length counter's previous value is lost). There is no immediate effect when enabled is set.

When clocked by the frame counter, the length counter is decremented except when:

  • The length counter is 0, or
  • The halt flag is set

Precise length counter period

In the actual APU, the length counter silences the channel when clocked while already zero. Hence an implementation that silences the channel when the length counter becomes zero will do so one frame counter clock early (though that most likely won't be audible). To simulate this in the disable-when-zero model of the length counter presented here, just add one to each entry in the table.

The triangle's linear counter works differently, and does silence the channel when it reaches zero.